Can you please let us know if we are missing anything Also, is there any other way to console into it Thanks.Tip: If the failing expression is known to be legally refer to something thats sometimes null or missing, either specify a default value like myOptionalVarmyDefault, or use when-present when-missing.These only cover the last step of the expression; to cover the whole expression, use parenthesis: (myOptionalVar.foo)myDefault, (myOptionalVar.foo).
Cisco Usb Console Software To UseThe two main aspects to think about when using Windows as a client for a console connection via the mini-USB cable are determining which COM port to connect to, and which terminal emulation software to use. Windows used to be shipped with HyperTerminal, so many people are accustomed to using that as a console client. HyperTerminal is licenced software (65), so that may not be what you want. Either tool, and others like them, will connect to a COM port. In Windows 10, before you insert the USB console cable, you can open the Device Manager to see the available COM ports (type Device Manager into the Cortana field). The Device Manager will display a tree of devices on your PC. Open Ports (COM LPT) and you may see some ports already (what you will see depends on your PCs configuration). Then, plug in the USB console cable and additional ports will appear. In my case COM4 and COM5, specifically Silicon Labs Dual CP210x USB to UART Bridge: Standard COM Port (COM4), and the same for COM5. Cisco Usb Console Serial Connection PurposesOne of those ports, COM4 or COM5 or whichever appears for you, will work for serial connection purposes with PuTTY, or other terminal emulators. You can run PuTTY by typing Putty in Cortana, and then selecting the PuTTY Desktop app icon that should appear. The PuTTY Configuration window will appear, defaulting to SSH settings. Select the Serial radio button and the fields will change to show a Serial line field and a Speed field. The Serial line field will have a default value, typically, of COM1. You will need to change that to one of the COM ports that appeared when you were looking at the Device Manager as described above, e.g. COM4. The Speed value should stay at the default of 9600. After changing the Serial line value, press return and a console window should appear with a prompt. If there is no prompt, try again with a different COM port value, COM5 say. Cisco Usb Console Drivers Required ToIt is possible that the drivers required to make this work are not present in your copy of Windows. Weve installed the appropriate drivers and the device is recognised on the COM6 and the COM7 port. The parameters that we have used are: Baud Rate - 9600, Data bits - 8, Parity - none, Stop bits - 1, Flow control - none. PFA a image of the putty console and the settings used for your reference.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |